Hip fractures mostly occur in elderly people with low bone strength. Bone strength is determined by bone mineral density (BMD), bone turnover, microarchitectural and geometrical properties of the bone. Dual energy x-ray absorptiometry (DXA) is the standard technique to measure BMD. However, BMD just provides information regarding the quantity of mineral in bone, which is only one component of bone strength. To date there is no reliable method to assess bone strength in vivo. Therefore, a method to assess bone strength beyond BMD would provide additional information regarding the patients' risk of bone related fixation failure after fracture fixation.
DensiProbe is a new diagnostic device that was developed for intra-operative assessment of mechanical stability of the bone in the proximal femur. It consists of a drill bit like tool and an electronic system to measure the peak torque to break-away of trabecular bone in the femoral head of patients undergoing DHS surgical treatment. In a cadaver study comparing bone mineral density measured by quantitative computed tomography with bone strength measured by DensiProbe a high correlation between these two parameters could be shown. In a clinical pilot study a significant correlation between DensiProbe measurements and BMD measured by DXA at the femoral neck in patients with hip fractures could be shown. However, no perfect correlation was expected because DensiProbe measures bone strength, which is only partly caused by BMD.
Bone related fixation failure, such as secondary loss of reduction, is influenced by bone strength, bone mineral density, fracture type, fracture reduction and primary positioning of the implant. The predictive value of DensiProbe measurements for secondary loss of reduction needs to be investigated. If DensiProbe turned out to be an effective screening tool for patients with low bone strength that are on higher risk of the aforementioned complications these patients may in future benefit from alternative treatment methods (e.g. augmentation techniques) in order to reduce bone related fixation failure.
The primary aim of the present study is to investigate if bone strength measured by DensiProbeTM Hip (DensiProbe) is an independent factor to predict secondary loss of reduction (screw migration of 5 mm or more and / or telescoping of 10 mm or more) in patients with hip fractures after fracture fixation with DHS.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| DensiProbe Hip | Device | DensiProbe (CE marked) is a mechanical probe, which is used intra-operatively to assess mechanical stability of the trabecular bone in the proximal femur. It consists of a drill bit like tool and an electronic system for measuring the peak torque to break-away of trabecular bone in the femoral head. DensiProbe measurements are designed to be integrated in the DHS surgical procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Migration of the screw in relation to the femoral head of 5 mm or more and/or Telescoping (shortening of the femoral neck) of 10 mm or more | 3 months |
| Measure | Description | Time Frame |
|---|---|---|
| Rate of complications | 3 months | |
| BMD values measured by DXA (contralateral hip) | Post OP | |
| Parker mobility score |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Norbert Suhm, MD | Universitätsspital Basel | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medizinische Universität | Innsbruck | Austria | ||||
| Wilhelminenspital |
Not provided
| Label | URL |
|---|---|
| Related Info | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 3 months |
| Vienna |
| Austria |
| Medizinische Hochschule Hannover | Hanover | Germany |
| Friedrich-Schiller Universität | Jena | Germany |
| Universitätsklinikum Münster | Münster | Germany |
| Twenteborg Ziekenhuis Almelo | Almelo | Netherlands |
| Universitätsspital | Basel | Canton of Basel-City | 4031 | Switzerland |
| Stadtspital Triemli | Zurich | Switzerland |
| ID | Term |
|---|---|
| D005264 | Femoral Fractures |
| D006620 | Hip Fractures |
| D010024 | Osteoporosis |
| ID | Term |
|---|---|
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
| D007869 | Leg Injuries |
| D025981 | Hip Injuries |
| D001851 | Bone Diseases, Metabolic |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided