The purpose of this study is to assess the efficiency of permanent biventricular pacing using three ventricular leads in terms of reduction in adverse cardiac events rates, improvement in cardiac capacity and patients' functional status in subjects with congestive heart failure and a physiologic (sinus) rhythm.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Triple-site group | Active Comparator | Triple-site resynchronization group |
|
| Standard resynchronization group | Active Comparator | Standard (double-site) resynchronization group |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cardiac resynchronization pacemaker (InSync Sentry or Concerto, Medtronic, Minneapolis, MN,USA) with two intracardiac leads | Device | Cardiac resynchronization with two intraventricular leads: one in the right ventricle and one in the left ventricle (via the coronary sinus) |
| Measure | Description | Time Frame |
|---|---|---|
| Combined end-point of alive status, freedom from hospitalization for HF or heart transplantation, relative ≥10% increase in LV ejection fraction, ≥10% in VO2max and ≥10% in 6MWD. | six months |
| Measure | Description | Time Frame |
|---|---|---|
| The occurrence of major adverse cardiovascular events (hospitalization for exacerbated HF requiring modification of pharmacotherapy, heart transplant or death). | five years |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Radosław Lenarczyk, M.D. | First Department of Cardiology, Silesian Medical University, Silesian Center for Heart Diseases | Principal Investigator |
| Zbigniew Kalarus, M.D. | First Department of Cardiology, Silesian Medical University, Silesian Center for Heart Diseases | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| First Department of Cardiology, Silesian Medical University, Silesian Center for Heart Diseases | Zabrze | 41-800 | Poland |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 18242737 | Background | Lenarczyk R, Kowalski O, Kukulski T, Pruszkowska-Skrzep P, Sokal A, Szulik M, Zielinska T, Kowalczyk J, Pluta S, Sredniawa B, Musialik-Lydka A, Kalarus Z. Mid-term outcomes of triple-site vs. conventional cardiac resynchronization therapy: a preliminary study. Int J Cardiol. 2009 Mar 20;133(1):87-94. doi: 10.1016/j.ijcard.2007.12.009. Epub 2008 Feb 19. | |
| 17631515 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Triple-site cardiac resynchronization | Device | Cardiac resynchronization pacemaker (InSync Sentry or Concerto, Medtronic, Minneapolis, MN,USA) with three intraventricular leads: one in the right ventricle and two in the left ventricle (via the coronary sinus). Two left ventricular leads connected with Y-connector (Lead Adaptor 2827, Medtronic, Minneapolis, MN, USA) |
|
| Lenarczyk R, Kowalski O, Kukulski T, Szulik M, Pruszkowska-Skrzep P, Zielinska T, Kowalczyk J, Pluta S, Duszanska A, Sredniawa B, Musialik-Lydka A, Kalarus Z. Triple-site biventricular pacing in patients undergoing cardiac resynchronization therapy: a feasibility study. Europace. 2007 Sep;9(9):762-7. doi: 10.1093/europace/eum140. Epub 2007 Jul 13. |
| 18402900 | Background | Leclercq C, Gadler F, Kranig W, Ellery S, Gras D, Lazarus A, Clementy J, Boulogne E, Daubert JC; TRIP-HF (Triple Resynchronization In Paced Heart Failure Patients) Study Group. A randomized comparison of triple-site versus dual-site ventricular stimulation in patients with congestive heart failure. J Am Coll Cardiol. 2008 Apr 15;51(15):1455-62. doi: 10.1016/j.jacc.2007.11.074. |
| 19635069 | Background | Lenarczyk R, Kowalski O, Sredniawa B, Pruszkowska-Skrzep P, Pluta S, Sokal A, Kukulski T, Stabryla-Deska J, Wozniak A, Kowalczyk J, Zielinska T, Mazurek M, Streb W, Zembala M, Kalarus Z. Triple-site versus standard cardiac resynchronization therapy study (TRUST CRT): clinical rationale, design, and implementation. J Cardiovasc Electrophysiol. 2009 Jun;20(6):658-62. doi: 10.1111/j.1540-8167.2008.01394.x. |
| 22651239 | Result | Lenarczyk R, Kowalski O, Sredniawa B, Pruszkowska-Skrzep P, Mazurek M, Jedrzejczyk-Patej E, Wozniak A, Pluta S, Glowacki J, Kalarus Z. Implantation feasibility, procedure-related adverse events and lead performance during 1-year follow-up in patients undergoing triple-site cardiac resynchronization therapy: a substudy of TRUST CRT randomized trial. J Cardiovasc Electrophysiol. 2012 Nov;23(11):1228-36. doi: 10.1111/j.1540-8167.2012.02375.x. Epub 2012 May 31. |
| 25319879 | Derived | Lenarczyk R, Jedrzejczyk-Patej E, Mazurek M, Szulik M, Kowalski O, Pruszkowska P, Sokal A, Sredniawa B, Boidol J, Kowalczyk J, Podolecki T, Mencel G, Kalarus Z. Quality of life in cardiac resynchronization recipients: association with response and impact on outcome. Pacing Clin Electrophysiol. 2015 Jan;38(1):8-17. doi: 10.1111/pace.12523. Epub 2014 Oct 15. |
| 24626998 | Derived | Kowalczyk J, Lenarczyk R, Kowalski O, Podolecki T, Francuz P, Pruszkowska-Skrzep P, Szulik M, Mazurek M, Jedrzejczyk-Patej E, Sredniawa B, Kalarus Z; Triple-Site Versus Standard Cardiac Resynchronization Trial (TRUST CRT) Investigators. Contrast-induced acute kidney injury in patients undergoing cardiac resynchronization therapy-incidence and prognostic importance. Sub-analysis of data from randomized TRUST CRT trial. J Interv Card Electrophysiol. 2014 Jun;40(1):1-8. doi: 10.1007/s10840-014-9887-x. Epub 2014 Mar 14. |
| 23487543 | Derived | Boidol J, Sredniawa B, Kowalski O, Szulik M, Mazurek M, Sokal A, Pruszkowska-Skrzep P, Kukulski T, Kalarus Z, Lenarczyk R; Triple-Site Versus Standard Cardiac Resynchronisation Trial (TRUST CRT) Investigators. Many response criteria are poor predictors of outcomes after cardiac resynchronization therapy: validation using data from the randomized trial. Europace. 2013 Jun;15(6):835-44. doi: 10.1093/europace/eus390. Epub 2013 Mar 13. |
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| D006331 | Heart Diseases |
| ID | Term |
|---|---|
| D002318 | Cardiovascular Diseases |
Not provided