The objective of this study is to evaluate the completeness of struts coverage and vessel wall response to the new generation JACTAX drug-eluting stent vs Taxus stent in de novo coronary artery lesions at 6 months post index procedure. To investigate the completeness of the coverage as well as the number of uncovered stent struts per section, high resolution (~ 10-15 µm axial) intracoronary Optical Coherence Tomography (OCT) will be used.
The risk of late stent thrombosis represents a major concern for patients treated with first generation drug-eluting stents (DES). Delayed healing and poor endothelialization are common findings in vessels treated with DES and are probably related to the amount of drug and polymer applied to a DES. There is evidence to suggest that polymer applications may influence the processes of inflammation and vessel healing. The JACTAX family of DES have been designed to provide a maximum amount of drug delivered directly to coronary vessel tissue while excluding polymer and drug from contact within the vessel lumen. The JACTAX stents are comprised of a currently marketed bare metal stent (Libertè™) coated exclusively on the ablumenal stent surface with a carrier containing a bioerodable polymer, Polylactide and paclitaxel. The objective of this prospective study is to measure the completeness of strut coverage and vessel wall response (strut malapposition, neointima disomogeneities in texture) to the JACTAX stents vs Taxus Libertè in de novo coronary artery lesions at 6 months post index procedure. Optical Coherence Tomography (OCT) that detects smaller degrees of stent strut coverage more accurately than IVUS will be used at 6 months follow-up. Intravascular ultrasound (IVUS) will be performed as per normal practice at any index procedures and at 6 months follow-up.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Active Comparator | Drug Eluting Stent |
|
| 2 | Active Comparator | Drug Eluting Stent |
|
| 3 | Active Comparator | Drug Eluting Stent |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| JACTAX Drug eluting stent | Device | Jactax stent placed in coronary artery |
|
| Measure | Description | Time Frame |
|---|---|---|
| Proportion of stent struts uncovered and/or malapposed at OCT | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Major Adverse Cardiac Events (MACE) | 12 and 24 months | |
| Stent Thrombosis | 12 and 24 months | |
| Target Lesion Revascularization |
Not provided
Inclusion Criteria:
General Inclusion Criteria
Angiographic Inclusion Criteria
Exclusion Criteria:
General Exclusion Criteria
Angiographic Exclusion Criteria
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Giulio Guagliumi, MD | Cardiovascular Department Ospedali Riuniti di Bergamo | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ospedali Riuniti di Bergamo | Bergamo | 24128 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17325255 | Background | Luscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, Virmani R. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation. 2007 Feb 27;115(8):1051-8. doi: 10.1161/CIRCULATIONAHA.106.675934. | |
| 17438147 | Background | Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007 May 8;115(18):2435-41. doi: 10.1161/CIRCULATIONAHA.107.693739. Epub 2007 Apr 16. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| JACTAX LD drug eluting stent | Device | JACTAX LD stent placed in coronary artery |
|
|
| Taxus Libertè | Device | Taxus Libertè stent placed in coronary artery |
|
|
| 12 and 24 months |
| Procedural success | through discharge |
| QCA parameters: mean lumen diameter, acute gain, late loss and binary restenosis (≥ 50% diameter stenosis) rate | 6 months |
| IVUS parameters: neointimal area volume, stent and area volumes, stent apposition, and percent net volume obstruction | 6 months |
| 16003026 | Background | Kang WC, Han SH, Choi KR, Ahn TH, Shin EK. Acute myocardial infarction caused by late stent thrombosis after deployment of a paclitaxel-eluting stent. J Invasive Cardiol. 2005 Jul;17(7):378-80. No abstract available. |
| 12438288 | Background | Virmani R, Liistro F, Stankovic G, Di Mario C, Montorfano M, Farb A, Kolodgie FD, Colombo A. Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation. 2002 Nov 19;106(21):2649-51. doi: 10.1161/01.cir.0000041632.02514.14. |
| 15306217 | Background | Carter AJ, Aggarwal M, Kopia GA, Tio F, Tsao PS, Kolata R, Yeung AC, Llanos G, Dooley J, Falotico R. Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model. Cardiovasc Res. 2004 Sep 1;63(4):617-24. doi: 10.1016/j.cardiores.2004.04.029. |
| 14744976 | Background | Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation. 2004 Feb 17;109(6):701-5. doi: 10.1161/01.CIR.0000116202.41966.D4. Epub 2004 Jan 26. |
| 17135281 | Background | Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007 Apr;28(8):961-7. doi: 10.1093/eurheartj/ehl413. Epub 2006 Nov 29. |
| 18655155 | Background | Guagliumi G, Sirbu V. Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv. 2008 Aug 1;72(2):237-47. doi: 10.1002/ccd.21606. |
| 20647562 | Derived | Guagliumi G, Sirbu V, Musumeci G, Bezerra HG, Aprile A, Kyono H, Fiocca L, Matiashvili A, Lortkipanidze N, Vassileva A, Popma JJ, Allocco DJ, Dawkins KD, Valsecchi O, Costa MA. Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI). Circ Cardiovasc Interv. 2010 Aug;3(4):367-75. doi: 10.1161/CIRCINTERVENTIONS.110.950154. Epub 2010 Jul 20. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |