Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Because the measurement of the retinal nerve fiber layer thickness is very sensitive to the position of measurement, it may be incorrect in patients with the tilted disc. In the present study, the corrected RNFL thickness by the optic nerve head configuration using the Cirrus HD OCT will be evaluated. If the corrected RNFL thickness is more sensitive to detect the localized RNFL defect, the present software should be upgrade to reflect the optic nerve head configuration.
Finding the localized retinal nerve fiber layer (RNFL) defect and measuring the RNFL thickness are two main issues for early glaucoma detection. A recently developed imaging device, the Cirrus HD OCT, offers more detailed informations about retina architecture including optic nerve head. To calculate the RNFL thickness, the software of the Cirrus HD OCT supposes an ideal optic nerve head. However, in the cases with not ideal optic disc configuration, the measurement of the RNFL thickness is not correct. Because the measurement of the RNFL thickness is extremely sensitive to the position of measurement, patients with the tilted disc are in danger of misdiagnosis. In the present study, we want to correct the RNFL thickness measurement according to the optic nerve head configuration using the Cirrus HD OCT. If the corrected RNFL thickness is more sensitive to detect the localized RNFL defect, the present software should be upgrade to reflect the optic nerve head configuration.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| C | normal volunteers | ||
| G | glaucoma patients |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| the Cirrus HD OCT | when the OCT images are taking |
| Measure | Description | Time Frame |
|---|---|---|
| automated visual field | when the OCT images are taking | |
| red-free fundus photo | when the OCT images are taking | |
| refractive errors |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Volunteers of our opthalmologic clinic
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Gong Je Seong, MD, PhD | Contact | 82-2-2019-3441 | gjseong@yuhs.ac |
| Name | Affiliation | Role |
|---|---|---|
| Gong Je Seong, MD, PhD | Yonsei University | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Gong Je Seong | Recruiting | Seoul | 135-720 | South Korea |
Not provided
| ID | Term |
|---|---|
| D005901 | Glaucoma |
| D009216 | Myopia |
| ID | Term |
|---|---|
| D009798 | Ocular Hypertension |
| D005128 | Eye Diseases |
| D012030 | Refractive Errors |
Not provided
Not provided
Not provided
Not provided
Not provided
| when the OCT images are taking |