The purpose of this scientific study is to clarify whether there is a relationship between the appearance of radiolucent lines in bone-cement interphase of the tibial component of the different models of the Oxford Uni Knee prosthesis and poor prognosis of these prostheses. This will be accomplished in a se-ries of three different Oxford Uni Knees.
The purpose of this scientific study is to clarify whether there is a relationship between the appearance of radiolucent lines in bone-cement interphase of the tibial component of the different models of the Oxford Uni Knee prosthesis and poor prognosis of these prostheses. This will be accomplished in a series of three different Oxford Uni Knees by studying:
The study would be considered a success if all designs of the prostheses are firmly fixed and remain so during the entire period of study, that is, no increasing migration is seen using RSA. It would be a success if the appearance of RLL beneath the implant in the proximal tibia is unrelated to bone loss and prosthesis migration.
The hypotheses are:
The primary parameters of effect are RLL, RSA and DEXA. The secondary parameters of effect are bone-remodeling, wear analysis, Oxford Knee Score (ADL) and ROM.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Active Comparator | Cemented single pegged femur with standard tibial bearing tray |
|
| 2 | Active Comparator | Cemented twin pegged femur with standard tibial bearing tray |
|
| 3 | Active Comparator | Cementless tibial bearing tray and femur (porous coated and HA coated) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Oxford Uni Knee | Device | Oxford Uni Knee inserted at the time of surgery |
|
| Measure | Description | Time Frame |
|---|---|---|
| Three way randomized comparison of migration (prosthetic fixation) by Model Based RSA with three different Oxford Uni Knee prosthesis (both tibial trays and femoral components will be assessed) | 2016 |
| Measure | Description | Time Frame |
|---|---|---|
| Fluoroscopy (screening) roentgenograms for determination of RLL around the tibial component and "overhang" of the tibial trays. | 2016 |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Kjeld Soballe, MD, Prof. | Orthopaedic Center, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Orthopaedic Center, Aarhus University Hospital | Aarhus | 8200 | Denmark |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36422666 | Derived | Jorgensen PB, Krag-Nielsen N, Lindgren L, Morup RMS, Kaptein B, Stilling M. Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography. Arch Orthop Trauma Surg. 2023 Sep;143(9):5919-5926. doi: 10.1007/s00402-022-04674-0. Epub 2022 Nov 23. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020370 | Osteoarthritis, Knee |
| ID | Term |
|---|---|
| D010003 | Osteoarthritis |
| D001168 | Arthritis |
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Oxford Uni Knee | Device | Oxford Uni Knee inserted at the time of surgery |
|
|
| Oxford Uni Knee | Device | Oxford Uni Knee inserted at the time of surgery (porous coated and HA coated) |
|
|
| D012216 |
| Rheumatic Diseases |