This study evaluated and optimized settings for, and evaluated the performance of, AI-700-enhanced echocardiographic imaging on several ultrasound imaging platforms, as well as collected additional safety data for AI-700 in healthy volunteers and stable cardiac patients.
Because the quality of AI-700-enhanced images is in part determined by the ultrasound (US) settings selection, the continuing study of different imaging modes and/or techniques is required in order to provide US settings recommendations for the many available systems. Therefore AI-700-enhanced imaging was performed in this study using imaging platforms and modes not previously tested and the AI-700 dose and administration methods employed in previous Phase 3 studies.
Two cohorts of subjects were studied at each site. Enrollment commenced with Cohort A and included normal (healthy) volunteers and stable cardiac patients. Settings optimization was performed in Cohort A using a single platform and real-time imaging. If the Sponsor agreed that the images and settings acquired in Cohort A were acceptable, the site was authorized to begin enrollment in Cohort B using the platform and settings that were defined in Cohort A. Authorized sites enrolled stable cardiac patients in Cohort B; no healthy volunteers were studied. For Cohort B subjects, the first 0.04 mL/kg dose of AI 700 was used to evaluate real-time imaging with the settings defined in Cohort A. The second dose of AI-700 for Cohort B subjects may have been used to confirm the data obtained with the first dose, or to explore imaging in a second mode (e.g. 3D/4D) and/or using real-time, high mechanical index triggered imaging on a second platform.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AI-700 | Drug |
| Measure | Description | Time Frame |
|---|---|---|
| Image quality of echocardiographic data collected via several ultrasound imaging platforms | ||
| For Cohort B, the duration of MCE following the first 0.04 mL/kg dose of AI-700 | ||
| Safety of AI-700 administered IV to healthy volunteers and suspected CAD patients |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Acusphere, Inc. | Watertown | Massachusetts | 02472 | United States |
Not provided
| Label | URL |
|---|---|
| Related Info | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| D006331 | Heart Diseases |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D002318 | Cardiovascular Diseases |
| D001161 | Arteriosclerosis |
Not provided
Not provided
| ID | Term |
|---|---|
| C108042 | perfluorobutane |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D001157 |
| Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |