The purpose of this study is to evaluate and document appropriate clinical safety and performance of the Remon CHF Implantable Pressure Sensor including the corresponding delivery system, the Remon CHF Home Unit, the Remon CHF Clinic System devices and associated application software. It is a small clinical trial to determine the feasibility of the device. The primary outcome measure relates to feasibility and not to health outcomes.
This study was a prospective feasibility, non-randomised, singlearm, multi-centre, interventional clinical investigation performed at 4 international sites. Patients were implanted with the Remon CHF Implantable Pressure Sensor utilizing the corresponding delivering system. Measurements were taken with the Remon CHF Home Unit and the Remon CHF Clinic System. Follow-up visits took place at one, three and six months after implant.
Per protocol, a minimum of 30 patients was required to demonstrate safety of the device.
The study was conducted in accordance with ISO 14155:2003 (parts I and II), the Declaration of Helsinki and all applicable local and national regulations in the countries of submission.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients implanted with Pressure Sensor | Experimental | Implant of Pressure sensor. These are patients, who were implanted with the Remon CHF Implantable Pressure Sensor utilizing the corresponding delivering system. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Implant of Pressure sensor. | Device | Implant of an Remon ImPressure implantable pulmonary artery pressure sensor utilizing the corresponding delivering system. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Serious adverse events related to implantation or the device | Primary Device Safety Objective: Serious Adverse Device Effects rate during 6 months following implantation (device or delivery system related) and Implantation related Serious Adverse Events rate during 6 months following implantation | 6 |
| Measure | Description | Time Frame |
|---|---|---|
| Device accuracy | Compare accuracy of Remon Pressure Sensor with Millar catheter (invasive way of measuring pulmonary artery pressure). Secondary end points included accuracy of the measured PA pressure, functionality of the system and evaluation of pressure readings at different postures. | 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Horst Sievert, M.D. | CardioVascular Center Frankfurt, Seckbacher | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19196733 | Result | Hoppe UC, Vanderheyden M, Sievert H, Brandt MC, Tobar R, Wijns W, Rozenman Y. Chronic monitoring of pulmonary artery pressure in patients with severe heart failure: multicentre experience of the monitoring Pulmonary Artery Pressure by Implantable device Responding to Ultrasonic Signal (PAPIRUS) II study. Heart. 2009 Jul;95(13):1091-7. doi: 10.1136/hrt.2008.153486. Epub 2009 Feb 5. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
No masking
Not provided