Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| POP053504 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Susan G. Komen Breast Cancer Foundation | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this study is to assess whether use of a mammography breast plate cushion will significantly decrease the level of discomfort experienced by African American women during routine screening mammograms. The primary hypothesis is that use of the breast plate cushion will result in less mammography-related discomfort. The secondary hypotheses are that women who anticipate high levels of discomfort will experience greater reductions in discomfort when a breast plate cushion is used and participants who received mammograms using a breast plate cushion will have greater intentions to return for a routine mammogram than the control group.
Despite improvements over the past decade, routine mammography screening rates among African American women remain suboptimal. This is especially troubling in light of the fact that African American women have higher breast cancer mortality rates than White and Hispanic women. Multiple studies have revealed that women experience varying levels of pain during mammography, however, African American women report higher levels of mammography-related pain than their White counterparts. In fact, the fear of pain associated with mammography is so prominent that it prevents some women from undergoing routine screenings or follow-ups. Since pain is a major barrier for many African American women in the screening process, studies to assess methods to reduce mammography-related pain are imperative. An FDA-approved radiolucent breast plate cushion has been developed for use during mammography to increase comfort during the exam. The purpose of this study is to evaluate whether use of this radiolucent cushion will decrease the level of pain experienced by African American women undergoing routine screening mammography, positively impact routine mammography screening intentions, and result in greater mammography satisfaction among African American women. 304 women scheduled for mammograms at three community metropolitan mammography facilities participated in this study. One-half of the women were randomized to an Enhanced Mammography (EM) condition in which a radiolucent cushion was used during mammograms. The other half were randomized to a Routine Mammography (RM) condition during which typical exam protocol is followed and no radiolucent cushion was used. Pre- and post-exam surveys assessed anticipated and experienced exam-related pain and discomfort, intentions to return for a future routine mammogram, and general visit satisfaction. A follow-up telephone interview will be conducted with study participants to determine whether they received a follow-up routine screening mammogram 12 to 18 months after they were enrolled in the study (at the time of their last routine screening mammogram) and where they received their mammogram (e.g. did they return to the same facility). If they did not obtain an on-time routine screening mammogram barriers were assessed. The RM and EM groups will be compared for differences.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Experimental | Enhanced Mammography (EM) - Women who are randomized to the Enhanced Mammography (EM) condition will receive a mammogram in which a MammoPad radiolucent breast plate cushion is used. |
|
| 2 | No Intervention | Routine Mammography (RM) - Women who are randomized to the Routine Mammography (RM) condition will obtain a routine, un-altered mammogram during which typical exam protocol will be followed and no radiolucent cushion is used. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Radiolucent cushion | Device | MammoPad radiolucent breast plate cushion used during mammogram |
|
| Measure | Description | Time Frame |
|---|---|---|
| A Pre-Mammography Survey and Post-Mammography Survey to assess anticipated and actual discomfort |
| Measure | Description | Time Frame |
|---|---|---|
| Pre-Mammography Survey, Post-Mammography Survey to assess barriers |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Kim K. Engelman, PhD | University of Kansas Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Kansas Medical Center | Kansas City | Kansas | 66160 | United States |
Not provided
| ID | Term |
|---|---|
| D001943 | Breast Neoplasms |
| ID | Term |
|---|---|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D001941 | Breast Diseases |
| D012871 | Skin Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D017437 |
| Skin and Connective Tissue Diseases |