Unacceptable incidence of wound dehiscence in the PDS group
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Within the last decade the customary trend of using non absorbable sutures has changed, with numerous studies and meta-analyses advocating the use of slowly absorbable sutures, claiming comparable wound strength with significantly lower incidence of wound complications. It was the objective of this randomized clinical trial to compare two universally accepted suture materials, the non-absorbable Nylon and the slowly absorbable Polydioxanone for midline abdominal closure in the Indian context.
64 patients undergoing midline laparotomy were allocated, using block randomization, to mass closure of the abdominal wall with continuous polyamide (34 patients) or continuous polydioxanone (30 patients).
There was an alarmingly higher incidence of wound dehiscence in the PDS group requiring secondary suturing (Nylon 0; PDS 5). Mid-way through the trial, an interim analysis was performed which revealed an unacceptably high incidence of wound dehiscence in the PDS group. This necessitated a premature curtailment of the study. There was, however, a statistically significantly higher incidence of scar pain in the Nylon group (Nylon 9; PDS 1).
There is a need for a study with larger series, and PDS as a choice of suture for midline wound closure cannot be recommended.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Active Comparator | Surgical Patient undergoing midline laparotomy closure |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Suture for midline abdominal closure | Device | closure with Polyamide or Polydioxanone |
|
| Measure | Description | Time Frame |
|---|---|---|
| Wound Complications associated with suture material used for closure- Wound Dehiscence, Wound Infection, Incisional Hernia, Suture Sinus, Scar Pain | 2 years |
| Measure | Description | Time Frame |
|---|---|---|
| Factors independent of suture materials responsible for wound complications such as age, gender, type of surgery, degree of contamination, surgeon, and presence of a stoma | 2 years |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Rajeev Kapoor, MS(Gen Surg) | Christian Medical College and Hospital, Ludhiana, India | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Christian Medical College and Hospital | Ludhiana | Punjab | 141008 | India |
Not provided
| ID | Term |
|---|---|
| D013537 | Sutures |
| ID | Term |
|---|---|
| D053831 | Surgical Fixation Devices |
| D013523 | Surgical Equipment |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided