Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Abiomed Inc. | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to evaluate the efficacy and safety of a left ventricular assist device in comparison to a standard treatment with an intraaortic balloon pump (IABP) in patients with cardiogenic shock due to left ventricular failure following an acute coronary syndrome (myocardial infarction).
Cardiogenic shock due to a left ventricular failure after myocardial infarction (MI) is associated with a mortality rate of 50-70 % despite all efforts such as immediate PCI of the occluded vessel, positive inotropic drugs, and the use of intraaortic balloon counterpulsation (IABP). While urgent heart transplantation or the surgical implantation of high-volume left ventricular assist devices are possible treatment options, a widespread use of these techniques for this common complication of myocardial infarction is limited. Because of the easy, percutaneous use of an intraaortic balloon pump, IABP is the method of choice for mechanical assistance in these patients. Despite a lack of randomized data, the ACC/AHA guidelines recommend the use of an intraaortic balloon counterpulsation (Level of evidence IB) in patients with a cardiogenic shock after myocardial infarction. However, improvement of the hemodynamic state by the use of an IABP is limited and the lack of an active cardiac support remains the major limitation of this treatment. Percutaneous left ventricular assist devices may both overcome the limitation of a surgical approach and offer the potential benefit of an active cardiac support during recovery of the failing left ventricle after PCI.
Previous studies have demonstrated a significant improvement of hemodynamic parameters by the use of a catheter-based miniaturized rotary blood pump (Impella LP2.5, Abiomed-Impella CardioSystems GmbH, Aachen, Germany), that is placed retrogradely through the aortic valve. The microaxial pump aspirates blood from the left ventricle and expels it to the ascending aorta with a maximal flow of 2.5 L/min. Randomized data comparing the LVAD with IABP are missing. Therefore, this trial will primarily compare the hemodynamic improvement of the LVAD (Impella LP2.5) with the hemodynamic improvement of an intraaortic balloon counterpulsation (IABP), while secondarily feasibility, safety and mortality will be compared.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Active Comparator | Intraaortic balloon counterpulsation (IABP) |
|
| 2 | Experimental | Left Ventricular Assist Device (Impella LP2.5) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Left Ventricular Assist Device Impella LP 2.5 | Device | Left Ventricular Assist Device |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Cardiac index | within 1 hour after device implantation |
| Measure | Description | Time Frame |
|---|---|---|
| Hemodynamic and metabolic parameters | until to hospital discharge | |
| Mortality | within 30 and 180 days | |
| device-related complications:hemolysis and major bleedings |
Not provided
Inclusion Criteria:
Acute coronary syndrome (ACS/AMI) < 48h and cardiogenic shock defined as:
Written informed consent of the patient or his/hers relatives
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Melchior Seyfarth, MD | Deutsches Herzzentrum Muenchen | Study Chair |
| Josef Dirschinger, MD | 1. Medizinische Klinik, Klinikum rechts der Isar | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Deutsches Herzzentrum Muenchen | Munich | 80636 | Germany | |||
| 1. Medizinische Klinik, Klinikum rechts der Isar |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16757723 | Background | Hochman JS, Sleeper LA, Webb JG, Dzavik V, Buller CE, Aylward P, Col J, White HD; SHOCK Investigators. Early revascularization and long-term survival in cardiogenic shock complicating acute myocardial infarction. JAMA. 2006 Jun 7;295(21):2511-5. doi: 10.1001/jama.295.21.2511. | |
| 10460813 | Background | Hochman JS, Sleeper LA, Webb JG, Sanborn TA, White HD, Talley JD, Buller CE, Jacobs AK, Slater JN, Col J, McKinlay SM, LeJemtel TH. Early revascularization in acute myocardial infarction complicated by cardiogenic shock. SHOCK Investigators. Should We Emergently Revascularize Occluded Coronaries for Cardiogenic Shock. N Engl J Med. 1999 Aug 26;341(9):625-34. doi: 10.1056/NEJM199908263410901. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012770 | Shock, Cardiogenic |
| D009203 | Myocardial Infarction |
| ID | Term |
|---|---|
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D007423 | Intra-Aortic Balloon Pumping |
| ID | Term |
|---|---|
| D015908 | Counterpulsation |
| D001243 | Assisted Circulation |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Intraaortic Balloon Pump |
| Device |
Counterpulsation |
|
| during hospitalization |
| Munich |
| 81675 |
| Germany |
| 10483976 | Background | Ryan TJ, Antman EM, Brooks NH, Califf RM, Hillis LD, Hiratzka LF, Rapaport E, Riegel B, Russell RO, Smith EE 3rd, Weaver WD, Gibbons RJ, Alpert JS, Eagle KA, Gardner TJ, Garson A Jr, Gregoratos G, Ryan TJ, Smith SC Jr. 1999 update: ACC/AHA guidelines for the management of patients with acute myocardial infarction. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Acute Myocardial Infarction). J Am Coll Cardiol. 1999 Sep;34(3):890-911. doi: 10.1016/s0735-1097(99)00351-4. No abstract available. |
| 19007597 | Derived | Seyfarth M, Sibbing D, Bauer I, Frohlich G, Bott-Flugel L, Byrne R, Dirschinger J, Kastrati A, Schomig A. A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction. J Am Coll Cardiol. 2008 Nov 4;52(19):1584-8. doi: 10.1016/j.jacc.2008.05.065. |
| D007238 |
| Infarction |
| D007511 | Ischemia |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D009336 | Necrosis |
| D012769 | Shock |