The objective of this study is to prospectively estimate the all-cause complication rates at 6-months for patients undergoing generator replacement due to elective replacement indicator (ERI), advisory, or upgrade without a planned system modification or with a planned system modification. Secondarily, this study aims to compare the influence of baseline variables contributing to the all-cause complication rates for subjects undergoing generator replacement.
Device replacements occur for many reasons, including elective replacement indication (ERI), manufacturer advisory, and upgrade.
Recently pacemaker and implantable cardioverter (ICD) advisories have created a dilemma for both physicians and patients. While the risk of device malfunction is low, replacement rates following an advisory are usually high and complication rates following device replacement are not widely known. One retrospective analysis of ICD advisories in Canada reported an 18.3% replacement rate, and subsequent 8.1% complication rate directly related to the replacement.
Device replacements also occur in order to upgrade an existing system. Clinical studies have shown that cardiac resynchronization therapy (CRT) significantly reduces all-cause mortality and hospitalization in patients with advanced heart failure (HF). As a result of expanding indications for this therapy, many standard ICD patients are being upgraded to CRT-D systems. Complication rates related to upgrades of these systems are also not widely known.
To our knowledge, the risk of complications following a device replacement has not been studied prospectively in any patient population. Limited data are available to guide physicians when weighing the risks and benefits of device replacement.
This is a prospective multi-center study. 1750 patients at 100 clinical sites will be enrolled prior to generator replacement. Patients will be implanted and followed for 6 months to assess any complications related to the replacement procedure.
Patients with any legally marketed device for explant can be enrolled. The replacement device can be from any manufacturer.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Straight-forward Device Replacement | Subject with a straight-forward device replacement without lead revisions or additions. |
| |
| Device Replacement with Upgrade | Subjects with a device replacement and planned lead upgrade, revision, or addition. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Straight-forward Device Replacement | Procedure |
| ||
| Device Replacement with Upgrade |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of Subjects Experiencing a Complication During Generator Replacement Without a Planned Lead Revision or Addition (Straight-forward Device Replacment) or With a Planned Lead Revision or Addition (Planned System Modification) | The percentage of subjects experiencing one of the pre-defined complications is presented. The percentage of subjects experincing a complication is presented separately for subjects with a straight-forward device replacment (generator replacement procedure plan did not include a lead addition or revision) and subjects with a planned system modification (generator replacement procedure plan did include a lead addition or revision). | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Subjects with device replacement procedures at study sites
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jeanne Poole, MD | University of Washington | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Alabama at Birmingham | Birmingham | Alabama | 35294 | United States | ||
| Mesa Cardiovascular |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25221331 | Derived | Chung MK, Holcomb RG, Mittal S, Steinberg JS, Gleva MJ, Mela T, Uslan DZ, Mitchell K, Poole JE; REPLACE Investigators. REPLACE DARE (Death After Replacement Evaluation) score: determinants of all-cause mortality after implantable device replacement or upgrade from the REPLACE registry. Circ Arrhythm Electrophysiol. 2014 Dec;7(6):1048-56. doi: 10.1161/CIRCEP.114.001671. Epub 2014 Sep 14. | |
| 22077194 |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | 'Straight-forward' Device Replacement | Cohort for patients undergoing a straight-forward device replacement without any planned system modification |
| FG001 | Replacement With Planned System Modification |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Procedure |
|
| Mesa |
| Arizona |
| 85206 |
| United States |
| Stanislaus Cardiology | Modesto | California | 95355 | United States |
| Desert Cardiology | Rancho Mirage | California | 92270 | United States |
| Mercy General Hospital | Sacramento | California | 95819 | United States |
| UCSD Medical Center | San Diego | California | 92103 | United States |
| UCSF | San Francisco | California | 94143 | United States |
| Penrose Hospital | Colorado Springs | Colorado | 80907 | United States |
| Aurora Denver Cardiology | Denver | Colorado | 80012 | United States |
| George Washington University | Washington D.C. | District of Columbia | 20037 | United States |
| Manatee Memorial | Bradenton | Florida | 34209 | United States |
| Halifax Medical Center | Daytona Beach | Florida | 32114 | United States |
| Baptist Jacksonville | Jacksonville Beach | Florida | 32250 | United States |
| Mt. Sinai Medical Center | Miami Beach | Florida | 33140 | United States |
| Wuesthoff Hospital | Rockledge | Florida | 32955 | United States |
| Bayfront Medical Center | St. Petersburg | Florida | 33705 | United States |
| University of South Florida | Tampa | Florida | 33606 | United States |
| Florida Medical Center | Zephyrhills | Florida | 33542 | United States |
| Piedmont Hospital | Atlanta | Georgia | 30309 | United States |
| Emory University Clinic | Atlanta | Georgia | 30322 | United States |
| The University of Chicago | Chicago | Illinois | 60637 | United States |
| Loyola University | Maywood | Illinois | 60153 | United States |
| University of Kansas Hospital | Kansas City | Kansas | 66160 | United States |
| Central Baptist | Lexington | Kentucky | 40503 | United States |
| Louisiana Heart | Lafayette | Louisiana | 70503 | United States |
| Tulane University | New Orleans | Louisiana | 70112 | United States |
| University of Maryland | Baltimore | Maryland | 21201 | United States |
| Midatlantic Cardiovascular Associates | Baltimore | Maryland | 21218 | United States |
| Union Memorial Hospital | Baltimore | Maryland | 21218 | United States |
| Shady Grove Adventist | Rockville | Maryland | 20850 | United States |
| Tufts University | Boston | Massachusetts | 02111 | United States |
| Massachusetts General Hospital | Boston | Massachusetts | 02114 | United States |
| New England Cardiovascular Specialists | Boston | Massachusetts | 02135 | United States |
| Lahey Clinic | Burlington | Massachusetts | 01805 | United States |
| North Shore Medical Center | Salem | Massachusetts | 01970 | United States |
| University of Michigan | Ann Arbor | Michigan | 48109 | United States |
| St. Joseph Mercy Hospital | Ypsilanti | Michigan | 48197 | United States |
| Forrest General Hospital | Hattiesburg | Mississippi | 39402 | United States |
| Mid America Heart | Kansas City | Missouri | 64111 | United States |
| Barnes Jewish Hospital | St Louis | Missouri | 63110 | United States |
| Heart Consultants Omaha | Omaha | Nebraska | 68122 | United States |
| Alegent Hospitals | Omaha | Nebraska | 68124 | United States |
| Creighton University | Omaha | Nebraska | 68131 | United States |
| St. Barnabas | West Orange | New Jersey | 07052 | United States |
| Buffalo Heart Group | Buffalo | New York | 14214 | United States |
| St. Luke's Roosevelt Hospital | New York | New York | 10025 | United States |
| Duke University Medical Center | Durham | North Carolina | 27715 | United States |
| Forsyth Medical Center | Winston-Salem | North Carolina | 27103 | United States |
| University of Cincinnati | Cincinnati | Ohio | 45267 | United States |
| University Hospitals Cleveland | Cleveland | Ohio | 44106 | United States |
| Heart and Vascular Center, MetroHealth MC | Cleveland | Ohio | 44109 | United States |
| Cleveland Clinic | Cleveland | Ohio | 44195 | United States |
| OU Medical Center Presbyterian | Oklahoma City | Oklahoma | 73104 | United States |
| Hillcrest Medical Center | Tulsa | Oklahoma | 74104 | United States |
| Sacred Heart Medical Center | Eugene | Oregon | 97401 | United States |
| Oregon Health Sciences University | Portland | Oregon | 97239 | United States |
| Abington Medical Specialists | Abington | Pennsylvania | 19454 | United States |
| University of Pennsylvania | Philadelphia | Pennsylvania | 19104 | United States |
| Thomas Jefferson University | Philadelphia | Pennsylvania | 19107 | United States |
| Medical University of South Carolina | Charleston | South Carolina | 29403 | United States |
| South Carolina Heart Center | Columbia | South Carolina | 29204 | United States |
| Pee Dee Cardiology | Florence | South Carolina | 29506 | United States |
| Spartanburg Regional Medical Center | Spartanburg | South Carolina | 29307 | United States |
| Vanderbilt University | Nashville | Tennessee | 37232 | United States |
| Amarillo Heart | Amarillo | Texas | 79106 | United States |
| Christus Spohn | Corpus Christi | Texas | 78404 | United States |
| UT Southwestern | Dallas | Texas | 75390 | United States |
| Heart Center of North Texas | Fort Worth | Texas | 76104 | United States |
| Sentara Norfolk General Hospital | Norfolk | Virginia | 23502 | United States |
| University of Washington | Seattle | Washington | 98195 | United States |
| CAMC Memorial Hospital | Charleston | West Virginia | 25304 | United States |
| Derived |
| Uslan DZ, Gleva MJ, Warren DK, Mela T, Chung MK, Gottipaty V, Borge R, Dan D, Shinn T, Mitchell K, Holcomb RG, Poole JE. Cardiovascular implantable electronic device replacement infections and prevention: results from the REPLACE Registry. Pacing Clin Electrophysiol. 2012 Jan;35(1):81-7. doi: 10.1111/j.1540-8159.2011.03257.x. Epub 2011 Nov 11. |
| 20921437 | Derived | Poole JE, Gleva MJ, Mela T, Chung MK, Uslan DZ, Borge R, Gottipaty V, Shinn T, Dan D, Feldman LA, Seide H, Winston SA, Gallagher JJ, Langberg JJ, Mitchell K, Holcomb R; REPLACE Registry Investigators. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation. 2010 Oct 19;122(16):1553-61. doi: 10.1161/CIRCULATIONAHA.110.976076. Epub 2010 Oct 4. |
Cohort for patients undergoing device replacement that includes a planned lead addition or revision. The complication rate is defined as the percentage of patients experiencing one or more major complication.
| COMPLETED |
|
| NOT COMPLETED |
|
|
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | 'Straight-forward' Device Replacement | Cohort for patients undergoing a straight-forward device replacement without any planned system modification |
| BG001 | Replacement With Planned System Modification | Cohort for patients undergoing device replacement that includes a planned lead addition or revision. The complication rate is defined as the percentage of patients experiencing one or more major complication. |
| BG002 | Total | Total of all reporting groups |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean | Standard Deviation | years |
| |||||||||||||||
| Sex: Female, Male | Count of Participants | Participants |
| ||||||||||||||||
| Region of Enrollment | Number | participants |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Percentage of Subjects Experiencing a Complication During Generator Replacement Without a Planned Lead Revision or Addition (Straight-forward Device Replacment) or With a Planned Lead Revision or Addition (Planned System Modification) | The percentage of subjects experiencing one of the pre-defined complications is presented. The percentage of subjects experincing a complication is presented separately for subjects with a straight-forward device replacment (generator replacement procedure plan did not include a lead addition or revision) and subjects with a planned system modification (generator replacement procedure plan did include a lead addition or revision). | Posted | Mean | 95% Confidence Interval | Percentage of participants (%) | 6 months |
|
|
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | 'Straight-forward' Device Replacement | Cohort for patients undergoing a straight-forward device replacement without any planned system modification | 0 | 1,031 | 0 | 1,031 | ||
| EG001 | Replacement With Planned System Modification | Cohort for patients undergoing device replacement that includes a planned lead addition or revision. The complication rate is defined as the percentage of patients experiencing one or more major complication. | 0 | 713 | 0 | 713 |
Not provided
Not provided
All information obtained from BIOTRONIK or PharmaLink concerning the research ideas used in this study and all information obtained under or concerning this study is considered BIOTRONIK property. Investigator will maintain such information in confidence and not release it to anyone without written consent from BIOTRONIK or prior public disclosure, with the exception of information required by law or regulations to be disclosed to the reviewing IRB, the patient, or the FDA.
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Crystal Miller, Clinical Studies Engineer | BIOTRONIK, Inc | 503-451-8051 | crystal.miller@biotronik.com |
| ID | Term |
|---|---|
| D011183 | Postoperative Complications |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| Male |
|