Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| TAXUS VI |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The clinical investigation is an international, prospective, multi-center, double-blind, randomized safety and efficacy trial. The purpose of this study is to evaluate the safety and effectiveness of the TAXUS(TM)Stent System with 1µg/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a moderate rate-release formulation of triblock copolymer carrier system in patients with a higher risk of target lesion revascularisation and restenosis.
The ultimate goal of a paclitaxel eluting stent system is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place.
The purpose of the TAXUS VI trial is to study the safety and efficacy of the TAXUS(TM)Stent under controlled trial circumstances and targets patients with a higher risk of target lesion revascularisation and restenosis. The study population will include longer lesions, smaller diameter vessels, multiple lesions in the same vessel, and allows for the use of up to 2 randomized study stents.
The clinical investigation will evaluate the safety and effectiveness of the TAXUS(TM)Stent with 1 µg/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a moderate rate-release formulation of a triblock copolymer carrier system for treatment of de novo coronary artery lesions.
Patients are stratified by site and presence or absence of medically treated diabetes mellitus and then randomized to receive either the TAXUS(TM)Stent or the uncoated EXPRESS(TM)stent.
The primary objective of the study is to show superior 9-month target vessel revascularization (TVR) rate for TAXUS(TM) Stent compared to uncoated Express(TM)control stent.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Arm 1 | Experimental |
| |
| Arm 2 | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TAXUS Express Paclitaxel-Eluting Coronary Stent System | Device | Paclitaxel-Eluting Coronary Stent System |
|
| Measure | Description | Time Frame |
|---|---|---|
| Rate of TVR 9 months after index procedure | 9 Months |
| Measure | Description | Time Frame |
|---|---|---|
| • Rates of composite Major Adverse Cardiac Events (MACE) and the individual components of MACE, assessed at 1, 3, 6 and 9 months after the study procedure and annually for 5 years (i.e., 1, 2, 3, 4, and 5 years after the study procedure). | 5 years | |
| Stent thrombosis rate. |
Not provided
Inclusion Criteria:
General Inclusion Criteria
Angiographic Inclusion Criteria
Exclusion Criteria:
General Exclusion Criteria:
Angiographic Exclusion Criteria
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Eberhard Grube, MD | HELIOS Clinic Siegburg, Germany | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| HELIOS Clinic | Siegburg | 53721 | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22496083 | Derived | Wakabayashi K, Mintz GS, Weissman NJ, Stone GW, Ellis SG, Grube E, Ormiston JA, Turco MA, Pakala R, Xue Z, Desale S, Laynez-Carnicero A, Romaguera R, Sardi G, Pichard AD, Waksman R. Impact of drug-eluting stents on distal vessels. Circ Cardiovasc Interv. 2012 Apr;5(2):211-9. doi: 10.1161/CIRCINTERVENTIONS.111.965780. Epub 2012 Apr 10. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Control stent | Device | control stent |
|
| 5 Years |
| Target Vessel Failure. | 5 years |
| Clinical procedural success. | Post procedure |
| Binary restenosis rate. | 9 months |
| • Additional angiographic endpoints at 9 month angiographic follow-up | 9 months |
| IVUS assessment in a subset of approximately 200 patients. At the baseline procedure (post-procedural) and at 9 month follow-up the absolute neointimal volume and the change in neointimal volume from post-procedure to follow-up will be analysed. | 9 months |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |