A new artificial lung device has been developed that potentially provides added support to mechanical ventilation for severely damaged lungs. The Hattler Respiratory Assist Catheter is designed to provide gas exchange (deliver oxygen and remove carbon dioxide) for a period of up to 7 days, providing more time for the lungs to improve.
Extrapolating from large animal data, the hypothesis is that the Hattler Catheter will be capable of providing 30% to 40% of the basal requirements of carbon dioxide exchange in a manner that is dependable and reproducible.
The Hattler Catheter Respiratory Assist Device consists of a Catheter and a drive console. The catheter consists of a bundle of polypropylene hollow fibers (approximately 1000) in 30cm or 35cm length surrounding a helium filled balloon. The balloon is similar to an Intra-Aortic Balloon, however, it is pulsed at 300 beats per minute, while IABP typically operate at 120 bpm. The hollow fibers are similar to fibers utilized in external oxygenators for cardio-pulmonary bypass. No device exists on the market in which fibers surround a balloon, and no device exists on the market in which the hollow fiber bundle is designed to be inserted into the venous system, i.e., the vena cava. External oxygenators are designed to be used in an extracorporeal circulatory loop.
The Hattler Catheter drive console provides the power to drive the helium filled balloon while removing excess oxygen and carbon dioxide from the venous system via the catheter.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Hattler Respiratory Assist Catheter | Device |
| Measure | Description | Time Frame |
|---|---|---|
| Effective insertion and removal as measured by hemostasis | ||
| Amount of effort required for both insertion and removal |
| Measure | Description | Time Frame |
|---|---|---|
| Peak gas exchange status within a maximum 7 day study |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Steven Tsui, MD | Papworth Hospital NHS Foundation Trust | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Papworth Hospital NHS Trust | Papworth Everard | Cambridge | CB3 8RE | United Kingdom |
Not provided
| ID | Term |
|---|---|
| D004646 | Emphysema |
| D012128 | Respiratory Distress Syndrome |
| D029424 | Pulmonary Disease, Chronic Obstructive |
| D001249 | Asthma |
| D012131 | Respiratory Insufficiency |
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D012120 | Respiration Disorders |
| D008173 | Lung Diseases, Obstructive |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D001982 | Bronchial Diseases |
| D012130 | Respiratory Hypersensitivity |
| D006969 | Hypersensitivity, Immediate |
| D006967 | Hypersensitivity |
| D007154 | Immune System Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |