The main objective of this study is to assess the safety and effectiveness of the sirolimus coated Bx VELOCITY stent in reducing angiographic in-stent late loss in de novo native coronary lesions as compared to the bare metal Bx VELOCITY balloon-expandable stent. Both stents will be mounted on the Raptor Rapid Exchange Delivery Stent System.
This is a multicenter (19 sites), prospective, randomized study. This study has a 2 arm design assessing the safety and effectiveness of the sirolimus coated BxTM VELOCITY stent to the bare metal BxTM VELOCITY stent, both mounted on the Raptorâ Rapid Exchange Stent Delivery System. A total of 220 patients will be entered in the study and will be randomized on a 1:1 basis. Patients will be randomized to the coated or uncoated BX VELOCITY stent. Therefore, neither the Investigator nor the patient will know which stent will be implanted. Patients will be followed for twelve months post-procedure, with all patients having a repeat angiography at 6 months. An ancillary study with in-stent IVUS measurements at 6 months follow-up will be performed in all patients of 6 pre-selected clinical sites. It is assumed that these sites will enroll more than 90 patients.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Active Comparator | Bare metal Bx Velocity™ Balloon-Expandable Stent mounted on the Raptor® rapid exchange delivery system |
|
| 2 | Experimental | Sirolimus coated modified Bx Velocity™ Balloon-Expandable Stent mounted on the Raptor® rapid exchange delivery system |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sirolimus coated Bx Velocityâ„¢ | Device | drug-eluting stent |
| |
| Bare metal Bx Velocityâ„¢ |
| Measure | Description | Time Frame |
|---|---|---|
| Angiographic in-stent late loss as determined by Quantitative Coronary Angiography. | 6 months follow-up |
| Measure | Description | Time Frame |
|---|---|---|
| In-stent mean %DS by QCA | post-procedure | |
| In-target vessel segment MLD | 6 months | |
| In-stent MLD |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Marie-Claude Morice, MD | Institut Hospitalier Jacques Cartier | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Dr Marie-Claude Morice | Massy | F- 91300 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17761505 | Background | Hoffmann R, Morice MC, Moses JW, Fitzgerald PJ, Mauri L, Breithardt G, Schofer J, Serruys PW, Stoll HP, Leon MB. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials. Heart. 2008 Mar;94(3):322-8. doi: 10.1136/hrt.2007.120154. Epub 2007 Aug 29. | |
| 15723977 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
bare-metal stent |
|
| 6 months |
| Target Lesion Revascularization | 6 and 12 months; or 2, 3, 4 and 5 years |
| Target Vessel Revascularization | 6 and 12 months; or 2, 3, 4 and 5 years |
| Major Adverse Cardiac Events | 30 days; 6 and 12 months; or 2, 3, 4 and 5 years; |
| Neo-intimal growth assessed by IVUS | 6 months |
| Result |
| Fajadet J, Morice MC, Bode C, Barragan P, Serruys PW, Wijns W, Constantini CR, Guermonprez JL, Eltchaninoff H, Blanchard D, Bartorelli A, Laarman GJ, Perin M, Sousa JE, Schuler G, Molnar F, Guagliumi G, Colombo A, Ban Hayashi E, Wulfert E. Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: three-year results of the RAVEL trial. Circulation. 2005 Mar 1;111(8):1040-4. doi: 10.1161/01.CIR.0000156334.24955.B2. Epub 2005 Feb 21. |
| 14720526 | Result | Abizaid A, Costa MA, Blanchard D, Albertal M, Eltchaninoff H, Guagliumi G, Geert-Jan L, Abizaid AS, Sousa AG, Wuelfert E, Wietze L, Sousa JE, Serruys PW, Morice MC; Ravel Investigators. Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients. Insights from the RAVEL Trial. Eur Heart J. 2004 Jan;25(2):107-12. doi: 10.1016/j.ehj.2003.11.002. |
| 12370218 | Result | Regar E, Serruys PW, Bode C, Holubarsch C, Guermonprez JL, Wijns W, Bartorelli A, Constantini C, Degertekin M, Tanabe K, Disco C, Wuelfert E, Morice MC; RAVEL Study Group. Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation. 2002 Oct 8;106(15):1949-56. doi: 10.1161/01.cir.0000034045.36219.12. |
| 12176950 | Result | Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, Guagliumi G, Wijns W, Lindeboom WK, Ligthart J, de Feyter PJ, Morice MC; RAVEL Study Group. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation. 2002 Aug 13;106(7):798-803. doi: 10.1161/01.cir.0000025585.63486.59. |
| 17903626 | Result | Morice MC, Serruys PW, Barragan P, Bode C, Van Es GA, Stoll HP, Snead D, Mauri L, Cutlip DE, Sousa E. Long-term clinical outcomes with sirolimus-eluting coronary stents: five-year results of the RAVEL trial. J Am Coll Cardiol. 2007 Oct 2;50(14):1299-304. doi: 10.1016/j.jacc.2007.06.029. Epub 2007 Sep 17. |
| 17296825 | Derived | Spaulding C, Daemen J, Boersma E, Cutlip DE, Serruys PW. A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med. 2007 Mar 8;356(10):989-97. doi: 10.1056/NEJMoa066633. Epub 2007 Feb 12. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |