Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| R01MH024652 | U.S. NIH Grant/Contract | View source | |
| 010807 | Other Identifier | University of Pittsburgh Institutional Review Board |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| National Institute of Mental Health (NIMH) | NIH |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study will compare the symptoms, experiences, and laboratory sleep characteristics of young adults with and without insomnia.
The overall aim of this research study is to compare the symptoms, experiences and laboratory sleep characteristics of young adults with and without insomnia. Insomnia is a pattern of difficulty falling asleep, staying asleep or feeling poorly rested despite an adequate amount of time for sleep, which occurs nearly every night for one month or longer. For those with insomnia, we will look at the effects of an intervention with one of two medications (escitalopram or zolpidem) or an inactive pill (placebo). This intervention will be followed by re-evaluation of symptoms, experiences and laboratory sleep characteristics. The three hypotheses being investigated are: compared to control subjects, those with insomnia will demonstrate affective disturbance and heightened arousal; the different medications will have different degrees of effect on the two dimensions being measured (affective disturbance and heightened arousal); and PET scans will reveal different patterns of activity in the brains of groups of people with insomnia.
We will specifically focus on the syndrome of Primary Insomnia (PI), defined by DSM-IV as insomnia that lasts for at least one month and causes significant impairment or distress. PI excludes insomnia that occurs exclusively during the course of another sleep, mental, substance-induced, or medical disorder. Insomnia is a significant public health problem because of its prevalence, morbidity, and the risk it poses for the development of subsequent mental disorders, particularly depressive and anxiety disorders. Understanding the psychobiology of primary insomnia is a critical step toward addressing questions regarding its relationships with mood and anxiety disorders.
Our model of insomnia builds on two major concepts running through previous insomnia research, affective disturbance and heightened arousal, as driving factors for the sleep-wake disturbances that define PI. Implicit in this model is that individuals with PI have different degrees of each dysfunction, which accounts for their heterogeneity of clinical symptoms. Contemporary theories of affect structure suggest that these two dimensions may be orthogonal in pure form, but are nevertheless related in clinical conditions characterized by mixed anxiety-depression, such as PI. Measures of affective disturbance and arousal in this study will include questionnaires, diary-based assessments, and physiological measures.
Pharmacological treatment probes may help to further distinguish the roles of affective disturbance and heightened arousal in insomnia. We will use a benzodiazepine receptor agonist (BzRA), zolpidem, and an antidepressant, escitalopram. BzRA potentiate the effects of GABA (1), but have minimal direct activity at any other receptor types. They are efficacious treatments for insomnia (2-4), but have little effect on mood. We chose zolpidem because it is relatively specific for hypnotic versus anxiolytic or other actions (5), because it is the most widely-prescribed BzRA hypnotic, and because it is well-tolerated (6). Clinically-effective doses of even "nonsedating" antidepressants can also improve symptoms in PI (7), suggesting that direct sedation is not their only mechanism for improving insomnia. We chose escitalopram because it is neither strongly alerting nor sedating in clinical and polysomnographic studies. This "sleep-neutral" profile will allow us to use it for its effects on affective disturbance, rather than its nonspecific sedating properties. Escitalopram's specific effect on serotonin reuptake blockade and its lack of affinity for Bz receptors distinguish it from zolpidem as a pharmacologic probe.
Functional neuroimaging studies in wakefulness and sleep may also help to identify the substrate of affective disturbance and heightened arousal in insomnia. Affective disturbance in the form of MDD is associated with alterations in both regional deactivation patterns during NREM sleep, and regional activation patterns during REM sleep. These observations suggest that a sleep-wake functional neuroimaging paradigm in insomnia patients, in conjunction with behavioral measures, may help to identify which brain systems mediate heightened arousal and affective disturbance, and how these systems interact.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Zolpidem | Experimental | The benzodiazepine receptor agonist (BzRA), zolpidem was given in an initial dose of 5 mg by mouth every night, 30 minutes prior to bedtime. The dose was increased to a maximum of 10 mg after the first week if there was no improvement in overall symptoms (CGI score of 4 or >). The dose was decreased to 5 mg if side effects occurred. |
|
| Excitalopram | Experimental | The antidepressant, escitalopram was initiated at 5 mg by mouth every night, 30 minutes prior to bedtime. If there were no side effects, the dose was increased every four days until the target dose of 20 mg (maximum dose) was reached by day 13. If significant side effects appeared, the highest tolerated dose was used. |
|
| Placebo | Placebo Comparator | A placebo capsule was given with instructions to take it every night by mouth, 30 minutes prior to bedtime. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Zolpidem | Drug | The benzodiazepine receptor agonist (BzRA), zolpidem was given in an initial dose of 5 mg by mouth every night, 30 minutes prior to bedtime. The dose was increased to a maximum of 10 mg after the first week if there was no improvement in overall symptoms (CGI score of 4 or >). The dose was decreased to 5 mg if side effects occurred. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Pittsburgh Sleep Quality Index | Self-report measure of sleep quality developed at University of Pittsburgh by Daniel J. Buysse, M.D. The PSQI total score ranges from 0 to 21 with 0 being marvelous sleep and 21 being horrid sleep. The difference score, reported below, is the total score after at least 5 weeks of treatment in one of the three arms, minus the baseline total score. A negative score means that the sleep of the participant improved. | post treatment minus baseline assessment battery. This averaged 100 days. |
| Change in Diary Sleep Efficiency | The change in self-report sleep efficiency calculated from 7-day sleep diary (DSE): Sleep efficiency is the percent of (time spent asleep divided by the amount of time between good night time and final awakening). It ranges from 0 (no sleep at all) to 100 (asleep the second your head hits the pillow until you wake up in the morning and get out of bed). Participants report the time they go to bed, how long they think it takes them to fall asleep, how many minutes they are awake during the night, and then what time they finally wake up in the morning. These values are used to calculate the diary sleep efficiency for each night and then we averaged these across the 7 days of diary collected pre and post treatment. The values below are post treatment DSE minus pre treatment DSE. A positive number means that the DSE was higher (better) post treatment. | post treatment minus baseline. This averaged 69 days. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in PSG Sleep Efficiency for the Second Night in the Sleep Lab at Each Timepoint | Change in PSG Sleep Efficiency (SE) between post-treatment and baseline: Sleep efficiency is the percent of time spent asleep divided by the total sleep recording period in the sleep lab. This value is calculated using the results of the polysomnographic sleep study. It ranges from 0 (no sleep at all) to 100 (asleep the second the sleep recording starts (GNT) until the sleep recording ends (GMT) in the morning). The values below are post treatment SE minus pre treatment SE. A positive number means that the SE was higher (better) post treatment. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Daniel J. Buysse, MD | University of Pittsburgh | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Western Psychiatric Institute and Clinic/ University of Pittsburgh Medical Center | Pittsburgh | Pennsylvania | 15213 | United States |
To gain access to data, researchers must submit a description of their project to the Principal Investigator, including the investigator's personal identification and institutional affiliation, a current CV, qualifications, duration of the proposed research, source of funding, and a conflict of interest statement. The protocol must include study aims, background and significance, methods and types of analysis, and a description of the data requested. Once approved, the investigator must complete a University of Pittsburgh IRB exempt research application form and document completion of a responsible conduct of research program. Data will be prepared by an 'honest broker' from the data management staff of the project. This person will complete the honest broker certification form required by our IRB. Data will be provided as a SAS data set, and will not include information that could identify individual research participants or that the original consent form expressly forbade.
Not provided
Not provided
Not provided
Not provided
Subjects who did not meet DSM-IV criteria for primary insomnia, had apnea or periodic limb movement disorder, or had an exclusionary psychiatric diagnosis (generalized anxiety disorder, major depressive disorder, substance abuse) were excluded.
Recruitment period lasted from 1/1/2002 to 12/1/2007. Subjects were recruited from the general public via tv, newspaper, and radio advertisements and via mass mailings.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Experimental: Zolpidem | The benzodiazepine receptor agonist (BzRA), zolpidem was given in an initial dose of 5 mg by mouth every night, 30 minutes prior to bedtime. The dose was increased to a maximum of 10 mg after the first week if there was no improvement in overall symptoms (CGI score of 4 or >). The dose was decreased to 5 mg if side effects occurred. |
| FG001 | Experimental: Excitalopram | The antidepressant, escitalopram was initiated at 5 mg by mouth every night, 30 minutes prior to bedtime. If there were no side effects, the dose was increased every four days until the target dose of 20 mg (maximum dose) was reached by day 13. If significant side effects appeared, the highest tolerated dose was used. |
| FG002 | Placebo Comparator: Placebo | A placebo capsule was given with instructions to take it every night by mouth, 30 minutes prior to bedtime. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Experimental: Zolpidem | The benzodiazepine receptor agonist (BzRA), zolpidem was given in an initial dose of 5 mg by mouth every night, 30 minutes prior to bedtime. The dose was increased to a maximum of 10 mg after the first week if there was no improvement in overall symptoms (CGI score of 4 or >). The dose was decreased to 5 mg if side effects occurred. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Secondary | Change in PSG Sleep Efficiency for the Second Night in the Sleep Lab at Each Timepoint | Change in PSG Sleep Efficiency (SE) between post-treatment and baseline: Sleep efficiency is the percent of time spent asleep divided by the total sleep recording period in the sleep lab. This value is calculated using the results of the polysomnographic sleep study. It ranges from 0 (no sleep at all) to 100 (asleep the second the sleep recording starts (GNT) until the sleep recording ends (GMT) in the morning). The values below are post treatment SE minus pre treatment SE. A positive number means that the SE was higher (better) post treatment. | Number of subjects who had polysomnography at Week 9 and at pretreatment. Some of the participants who 'completed' the protocol did not have follow up sleep studies. | Posted | Mean | Standard Deviation | difference score for SE | post treatment minus baseline PSG sleep studies. This averaged 70 days |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Zolpidem | Participants receiving an benzodiazepine receptor agonist (BzRA), zolpidem |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Inpatient Hospitalization | Vascular disorders | Systematic Assessment | Participant reported a hospitalization for hypertension |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Skin irritation related to EEG electrode placement | Skin and subcutaneous tissue disorders | Non-systematic Assessment | Participant reported some skin irritation at the site of electrode placement. |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Jean Miewald | University of Pittsburgh | 412-246-6406 | miewaldjm@upmc.edu |
Not provided
| ID | Term |
|---|---|
| D012893 | Sleep Wake Disorders |
| D007319 | Sleep Initiation and Maintenance Disorders |
| ID | Term |
|---|---|
| D009422 | Nervous System Diseases |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D000077334 | Zolpidem |
| D000089983 | Escitalopram |
| D015283 | Citalopram |
| ID | Term |
|---|---|
| D011725 | Pyridines |
| D006573 | Heterocyclic Compounds, 1-Ring |
| D006571 | Heterocyclic Compounds |
| D011437 | Propylamines |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Escitalopram | Drug | The antidepressant, escitalopram was initiated at 5 mg by mouth every night, 30 minutes prior to bedtime. If there were no side effects, the dose was increased every four days until the target dose of 20 mg (maximum dose) was reached by day 13. If significant side effects appeared, the highest tolerated dose was used. |
|
|
| Placebo | Drug | A placebo capsule was given with instructions to take it every night by mouth, 30 minutes prior to bedtime. |
|
|
| post treatment minus baseline PSG sleep studies. This averaged 70 days |
| BG001 |
| Experimental: Excitalopram |
The antidepressant, escitalopram was initiated at 5 mg by mouth every night, 30 minutes prior to bedtime. If there were no side effects, the dose was increased every four days until the target dose of 20 mg (maximum dose) was reached by day 13. If significant side effects appeared, the highest tolerated dose was used. |
| BG002 | Placebo Comparator: Placebo | A placebo capsule was given with instructions to take it every night by mouth, 30 minutes prior to bedtime. |
| BG003 | Total | Total of all reporting groups |
| Participants |
|
| Age, Continuous | Mean | Standard Deviation | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
Participants receiving an benzodiazepine receptor agonist (BzRA), zolpidem |
| OG001 | Escitalpram | Participants receiving an antidepressant, escitalopram |
| OG002 | Placebo | Participants receiving a placebo |
|
|
| Primary | Change in Pittsburgh Sleep Quality Index | Self-report measure of sleep quality developed at University of Pittsburgh by Daniel J. Buysse, M.D. The PSQI total score ranges from 0 to 21 with 0 being marvelous sleep and 21 being horrid sleep. The difference score, reported below, is the total score after at least 5 weeks of treatment in one of the three arms, minus the baseline total score. A negative score means that the sleep of the participant improved. | Number of subjects who had total PSQI scores after at least 5 weeks of treatment. The PSQI requires that all questions be answered for a total score to be calculated. This analysis includes participants who did not complete the protocol and also omits those who has missing total scores due to missing items on the PSQI | Posted | Mean | Standard Deviation | difference score of PSQI total | post treatment minus baseline assessment battery. This averaged 100 days. |
|
|
|
| Primary | Change in Diary Sleep Efficiency | The change in self-report sleep efficiency calculated from 7-day sleep diary (DSE): Sleep efficiency is the percent of (time spent asleep divided by the amount of time between good night time and final awakening). It ranges from 0 (no sleep at all) to 100 (asleep the second your head hits the pillow until you wake up in the morning and get out of bed). Participants report the time they go to bed, how long they think it takes them to fall asleep, how many minutes they are awake during the night, and then what time they finally wake up in the morning. These values are used to calculate the diary sleep efficiency for each night and then we averaged these across the 7 days of diary collected pre and post treatment. The values below are post treatment DSE minus pre treatment DSE. A positive number means that the DSE was higher (better) post treatment. | The number of subjects with sleep diaries at baseline and after at least 5 weeks of treatment. Not all of these participants 'completed' the protocol | Posted | Mean | Standard Deviation | diff score of diary Sleep Efficiency | post treatment minus baseline. This averaged 69 days. |
|
|
|
| 0 |
| 26 |
| 0 |
| 26 |
| EG001 | Escitalopram | Participants receiving an antidepressant, escitalopram | 0 | 23 | 2 | 23 |
| EG002 | Placebo | Participants receiving a placebo | 1 | 20 | 0 | 20 |
|
|
| Collodian remover splashed in eye | Eye disorders | Non-systematic Assessment | During electrode removal, the collodian remover splashed into one of the participant's eyes. |
|
Not provided
Not provided
| D001523 | Mental Disorders |
| D020919 | Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D000588 |
| Amines |
| D009930 | Organic Chemicals |
| D009570 | Nitriles |
| D001572 | Benzofurans |
| D006574 | Heterocyclic Compounds, 2-Ring |
| D000072471 | Heterocyclic Compounds, Fused-Ring |