RIGHT is a randomized, prospective, two-arm study that will assess the differential efficacy of VITALITY 2 implantable cardioverter defibrillators (ICDs) using Rhythm IDâ„¢ versus selected Medtronic ICDs.
RIGHT will compare the incidence of Ventricular Tachycardia/Fibrillation (VT/VF) therapies delivered for Supraventricular Tachycardia (SVT) episodes using VITALITY 2 devices with Rhythm IDâ„¢ to that of ICDs employing other rhythm discrimination algorithms. Appropriateness of therapies will be assessed after independent adjudication of all VT/VF events leading to therapy. Comparisons will be made between device manufacturers across patient populations receiving either a dual- or single-chamber device.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Implantable Cardioverter Defibrillator - Boston Scientific | Active Comparator | VITALITY 2 ICD |
|
| Implantable Cardioverter Defibrillator - Medtronic | Active Comparator | Selected Medtronic family ICD |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| VITALITY 2 Implantable Cardioverter Defibrillator | Device | VITALITY 2 ICD |
|
| Measure | Description | Time Frame |
|---|---|---|
| Number of Patients With Inappropriate Ventricular Tachycardia (VT)/Ventricular Fibrillation (VF) Therapy (Shock or Antitachycardia Pacing [ATP]) After the Pre-Discharge Visit | An inappropriate therapy is defined as a VT/VF therapy, either shock or antitachycardia pacing (ATP), delivered for a supraventricular tachycardia (SVT). All events for which a VT/VF therapy was delivered and a stored electrogram exists were reviewed by an independent adjudication committee to determine the appropriateness of device rhythm classification and subsequent therapy delivery. | From date of pre-discharge until a minimum of 12 months follow-up until study closure |
| Measure | Description | Time Frame |
|---|---|---|
| Time to First Inappropriate Shock Using VITALITY and Selected Medtronic Implantable Cardioverter Defibrillator (ICDs) | Time of event | |
| Positive Predictive Value (PPV) of Ventricular Tachycardia/Fibrillation (VT/VF) Discrimination Algorithms Found in VITALITY 2 and Medtronic Implantable Cardioverter Defibrillators (ICDs) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Gold, MD, PhD | Medical University of South Carolina | Principal Investigator |
| Ron Berger, MD, PhD | Johns Hopkins University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of South Carolina | Charleston | South Carolina | 29425 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16836672 | Result | Berger RD, Lerew DR, Smith JM, Pulling C, Gold MR. The Rhythm ID Going Head to Head Trial (RIGHT): design of a randomized trial comparing competitive rhythm discrimination algorithms in implantable cardioverter defibrillators. J Cardiovasc Electrophysiol. 2006 Jul;17(7):749-53. doi: 10.1111/j.1540-8167.2006.00463.x. | |
| 21978966 | Derived |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | VITALITY 2 | VITALITY 2 ICD |
| FG001 | Medtronic Family | Selected Medtronic family devices |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | VITALITY 2 | VITALITY 2 ICD |
| BG001 | Medtronic Family | Selected Medtronic family devices |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Number of Patients With Inappropriate Ventricular Tachycardia (VT)/Ventricular Fibrillation (VF) Therapy (Shock or Antitachycardia Pacing [ATP]) After the Pre-Discharge Visit | An inappropriate therapy is defined as a VT/VF therapy, either shock or antitachycardia pacing (ATP), delivered for a supraventricular tachycardia (SVT). All events for which a VT/VF therapy was delivered and a stored electrogram exists were reviewed by an independent adjudication committee to determine the appropriateness of device rhythm classification and subsequent therapy delivery. | Posted | Number | Participants | From date of pre-discharge until a minimum of 12 months follow-up until study closure |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | VITALITY 2 | This study did not collect serious adverse events |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Pulse generator Related | Cardiac disorders | Systematic Assessment |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Greg Voss, Clinical Director | Boston Scientific | 651-581-3068 | gregory.voss@bsci.com |
Not provided
| ID | Term |
|---|---|
| D013610 | Tachycardia |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D000075224 | Cardiac Conduction System Disease |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Medtronic Implantable Cardioverter Defibrillator | Device | Maximo, Marquis, Intrinsic, Virtuoso, or Entrust ICD |
|
| Time of event |
| Time to First Inappropriate Therapy for Which the Discrimination Algorithm Found in VITALITY 2 and Medtronic Implantable Cardioverter Defibrillator (ICDs) Inappropriately Classified the Episode | Time of event |
| Gold MR, Ahmad S, Browne K, Berg KC, Thackeray L, Berger RD. Prospective comparison of discrimination algorithms to prevent inappropriate ICD therapy: primary results of the Rhythm ID Going Head to Head Trial. Heart Rhythm. 2012 Mar;9(3):370-7. doi: 10.1016/j.hrthm.2011.10.004. Epub 2011 Oct 4. |
| BG002 |
| Total |
Total of all reporting groups |
| Participants |
|
| Age Continuous | Mean | Standard Deviation | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
Selected Medtronic family devices |
|
|
|
| Secondary | Time to First Inappropriate Shock Using VITALITY and Selected Medtronic Implantable Cardioverter Defibrillator (ICDs) | Not Posted | Time of event |
| Secondary | Positive Predictive Value (PPV) of Ventricular Tachycardia/Fibrillation (VT/VF) Discrimination Algorithms Found in VITALITY 2 and Medtronic Implantable Cardioverter Defibrillators (ICDs) | Not Posted | Time of event |
| Secondary | Time to First Inappropriate Therapy for Which the Discrimination Algorithm Found in VITALITY 2 and Medtronic Implantable Cardioverter Defibrillator (ICDs) Inappropriately Classified the Episode | Not Posted | Time of event |
| 0 |
| 0 |
| 535 |
| 985 |
| EG001 | Medtronic Family | This study did not collect serious adverse events | 0 | 0 | 508 | 977 |
| Right atrial lead related | Cardiac disorders | Systematic Assessment |
|
| Right ventricular lead related | Cardiac disorders | Systematic Assessment |
|
| Procedure related | Cardiac disorders | Systematic Assessment |
|
| Cardiovascular related | Cardiac disorders | Systematic Assessment |
|
| Other | Cardiac disorders | Systematic Assessment |
|
Not provided
Not provided
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |